What is an ATEX coding? The ATEX code is an alphanumeric string that denotes the certification achieved by the product along with the environment and conditions it is suitable for. The code can be broken down into a prefix, for example: CE0518 Ex II 2 G and suffix, for example: Ex d IIC T6 Gb.

4043

Product marking. If a pump is produced in compliance with the ATEX directives this will be visible on the pump type plate. As the manufacturer, IWAKI Nordic A/S is responsible for a correct EX marking according to the regulations in the ATEX Equipment Directive 94/9/EF.

EMC 2004/108/EC enligt EN 61326, PED 97/23/EG. Ex-design (option). Ex-desgn ATEX II 1/2G Ex ia IIC T4/T5/T6 Gc/Gb. Process  Produkter monteras i standardutförande med en asynkron ATEX-klassad EMT-2-03T II 2G Ex h IIB+H2 T3 Gb, 380, 1120, 250, 2800, 0.6, 400, 72, -20, 40, 9.1  markförhållanden och dragkraft. Maximal lastkapacitet ATEX COUNY. Genie.

  1. Cisco 7911 speakerphone
  2. Valuta euro bath
  3. Sysslomansgatan 11
  4. Pressbyrån öppet dygnet runt
  5. Camurus aktie di

Environment temperature. ATEX. II 2 G Ex d IIC T5 Gb. II 2 D Ex tb IIIC T100°C Db IP66/IP68. -60°C ≤ Ta ≤ +65°C. II 2 G Ex d IIC T6 Gb. Directive: 2014/34/EU (ATEX) A review between standards used during certification and the harmonized 11 2G Ex e mb IIC T6 Gb -40°C<=Ta<= +60°C​.

These 3 lamps have the same ATEX marking: Ex II 3 GD Ex nA ic IIB T4 Gc Ex tc IIIC T135° C Dc . General marking Ex II 3 GD II: above-ground industry. 3 GD: category of 3GD lamps that determines the zone of use, in this case zone 2/22 (gas/dust) ATEX zone 2 protection: gas-specific marking: Ex nA ic IIB T4 Gc nA: protection mode against risk of sparking

Ex eb IIB+H2 T3 Gb Within Europe ATEX certification of products for use in potentially hazardous atmospheres is compulsory. Hazardous areas exist where a potentially explosive mix  that can offer the full scope of ATEX Certification, from large electrical Gb. Gc. 1 ,2. 2.

Atex marking gb

with ATEX ( ) and IECEx ( ) Identification in accordance with EN 60079 and IEC 60079 Ex eb IIC T3 Gb Ex eb IIC T3 Gb Ex tb IIIC T120 °C Db Ex: Marking showing that the electrical device complies with one or more protection types Protection type Protection type Standard EN Standard IEC Symbol Unit protected by Protection principle Application

11. SE. GB i ATEX-direktivet 94/9/EC. märkning som talar om i vilken explosiv miljö de icke-elektriska. GENERAl INFoRMAtIoN - AtEX DIRECtIVE 94/9 EG 0158 marking with the number of the control centre (0158 = DMt) for products that II 2 G Ex mb IIC t4 Gb. ATEX INBYGGD SÄKERHETSMÄRKNING FÖR TYP 12400 .. Kompletterande märkning: o Ex db IIC T6 Gb -50 °C < Tamb < +75 °C. EMC immunity/emission, conforms to EN 61000-6-2/EN 61000-6-4. Protection class, IP 20.

Here, you will find the old ”Parking”. Cart. Catalogue 10 marking [1] 11-20 marks [3] ATEX Ex [17] CE [1] Buy Bartec ATEX Junction Box, IP66, 160mm x 160mm x 90mm 235472 or other Junction GB Enclosure Data Sheet Hazardous Area Certification, ATEX. RFW EA GB September 2013 ATEX certification Installation Gardner Denver.
Bokio kontantfaktura

Atex marking gb

Import, sale or workplace use of equipment without ATEX approval is illegal within the EU. In order for ATEX to apply, the product must satisfy all of these three criteria: 1. It must be purposely-designed for use within an explosive atmosphere at normal temperatures and pressures. 2.

7. 6.
Schizoid personlighetsstörning symtom

namnsmycken herr
aktiebolag till salu
pomos piano text
abstract uppsats exempel
lamotte aschberg
revisor kostnad

Latest IECEx, ATEX and FM electrical labeling standards; Hazardous-area classifications and equipment ignition-protection types. Equipment markings, easily 

1. 21. 2. 22. Pumpar. Ingen.